500T Configuration
The largest diameter in the table creates a distinct space and structural-design requirement.
The 500 t silo provides the upper storage reference in this published range. A 6 m diameter and 28.8 m total height define its listed vertical geometry.

Series rendering. Confirm 500T's appearance and included equipment in its proposal.
The listed 6 m diameter and 28.8 m total height define the preliminary geometry of this 500T cement storage option.
Study it as a bulk cement logistics decision covering deliveries, usable stock, filling and discharge for larger concrete operations.
The largest diameter in the table creates a distinct space and structural-design requirement.
A Φ407 screw reference and JS3000–JS6000 mixer association position it alongside larger production arrangements.
Understand the role of each connection before building the equipment package.
INTERFACE 01 / Screw ConveyorThe source pairs this size with a Φ407 reference.
Obtain the final conveyor duty and connection drawing for the complete powder route.
INTERFACE 02 / Stationary Concrete Batching PlantThe JS3000–JS6000 mixer associations do not guarantee one prescribed plant match.
Define cement demand and replenishment across the proposed operation.
INTERFACE 03 / Foundation Free Concrete Batching PlantThe larger vessel needs independently assessed foundations and support loads.
Separate that design from the receiving plant's base format.
INTERFACE 04 / Cement FeederIncoming bulk supply must be planned at the same scale as inventory.
Specify actual filling capacity and interfaces from the approved logistics brief.
Options and alternative architectures are identified in each explanation. This is not a pre-approved matched package. Final connections, duty and supplied components require a model-specific technical review.
Review My Equipment CombinationSeparate the key systems to see what each contributes to the operation.
500T functional separation illustration. Blocks identify subsystem roles; they do not reproduce the machine geometry, assembly sequence or fastening details. Request the approved model drawing for engineering use.
| Parameter | 500T |
|---|---|
| Silo diameter | Φ6M |
| Silo body height | 22.2m |
| Total height | 28.8m |
| Mixer reference | JS3000-JS6000 |
| Screw diameter reference | Φ407 |
Published EPDAS specifications are a reference for equipment selection. Final specifications and included equipment are confirmed in the quotation.
Original EPDAS Technical Reference ↗| Selection reference | 500T · This model | 300T | 200T |
|---|---|---|---|
| Silo diameter | Φ6M | Φ4.5m | Φ4.5m |
| Silo body height | 22.2m | 24.6m | 18.6m |
| Total height | 28.8m | 29.5m | 25.2m |
| Mixer reference | JS3000-JS6000 | JS2000-JS4000 | JS1500-JS3500 |
| Screw diameter reference | Φ407 | Φ323/Φ407 | Φ273/Φ323 |
Assess 500 t storage as part of a complete cement logistics study covering deliveries, filling, discharge and structural support.
Silo diameter: Φ6M
Silo body height: 22.2m
Total height: 28.8m
Confirm core equipment, options, buyer-provided systems, transport modules, inspection documents and support responsibilities in the quotation.