The source provides inlet flange dimensions A 200, B 250 and C 280 mm for checking the proposed interface.
The Φ140 mm screw conveyor appears in the installation-dimension table and as a matching reference for the 30 t silo. It is the smallest pipe diameter listed there.

Series rendering. Confirm 140mm's appearance and included equipment in its proposal.
The Φ140 option defines a powder-transfer connection size, with installation geometry available but no separately stated capacity rating.
Assess it for a smaller powder system only after feed duty and drive selection have been supplied.
The source provides inlet flange dimensions A 200, B 250 and C 280 mm for checking the proposed interface.
Three inclination bands are documented for inlet and outlet height references.
Understand the role of each connection before building the equipment package.
INTERFACE 01 / Cement SiloThe source lists Φ140 among the 30T silo references.
Confirm flange geometry and material duty before treating that association as a match.
INTERFACE 02 / Stationary Concrete Batching PlantThe receiving plant scale sets the actual feeding requirement.
Obtain batch cement mass and the permitted dosing interval for the smaller screw.
INTERFACE 03 / Mobile Concrete Batching PlantA mobile layout adds dismantling and reconnection constraints.
Verify actual inlet and outlet positions rather than assuming a standard portable length.
INTERFACE 04 / Cement FeederUpstream cement transfer and silo discharge are different tasks.
Establish whether the proposed feeder fills storage or supplies the receiving process.
Options and alternative architectures are identified in each explanation. This is not a pre-approved matched package. Final connections, duty and supplied components require a model-specific technical review.
Review My Equipment CombinationSeparate the key systems to see what each contributes to the operation.
140mm functional separation illustration. Blocks identify subsystem roles; they do not reproduce the machine geometry, assembly sequence or fastening details. Request the approved model drawing for engineering use.
| Parameter | 140mm |
|---|---|
| Inlet flange A (mm) | 200 |
| Inlet flange B (mm) | 250 |
| Inlet flange C (mm) | 280 |
| Inlet H1, 0–20° (mm) | 400 |
| Inlet H1, >20–40° (mm) | 450 |
| Inlet H1, >40–50° (mm) | 500 |
| Outlet H2, 0–20° (mm) | 250 |
| Outlet H2, >20–40° (mm) | 300 |
| Outlet H2, >40–50° (mm) | 350 |
Published EPDAS specifications are a reference for equipment selection. Final specifications and included equipment are confirmed in the quotation. Conveying capacity depends on material, inclination, length and feed conditions. Installation flange dimensions must be checked against the final drawing.
Original EPDAS Technical Reference ↗| Selection reference | 140mm · This model | 168mm | 219mm |
|---|---|---|---|
| Reference capacity | Not listed in this model reference | 24t/h | 40t/h |
| Inlet flange A (mm) | 200 | 200 | 300 |
| Inlet flange C (mm) | 280 | 280 | 380 |
| Inlet H1, 0–20° (mm) | 400 | 400 | 500 |
| Outlet H2, 0–20° (mm) | 250 | 250 | 300 |
Consider the 140 mm option only after confirming its required feed rate and drive selection, which are not separately rated in the capacity table.
Inlet flange A (mm): 200
Inlet flange B (mm): 250
Inlet flange C (mm): 280
Confirm core equipment, options, buyer-provided systems, transport modules, inspection documents and support responsibilities in the quotation.