Tubular screw conveyors

Φ407 Mm Screw Conveyor

The Φ407 mm screw conveyor is listed with a 170 t/h capacity reference. It is the largest pipe diameter in both the installation and conveying-capacity tables.

EPDAS Screw Conveyor series reference for 407mm

Series rendering. Confirm 407mm's appearance and included equipment in its proposal.

WHAT IS 407mm?

The Largest Listed Screw Diameter And Feed Reference

The Φ407 option is published at 170 t/h reference capacity with the largest flange format in the current screw range.

WHERE IT WORKS

Review it as part of a large powder-handling study, including the specific drive and installation drawing for the selected length.

01

407mm Configuration

A 470/470/530 mm inlet flange reference differentiates its connections from the smaller conveyor sizes.

02

407mm Selection Detail

Published drive-code entries extend through 13 m; longer configurations need a separate selection rather than an assumed standard drive.

407mm / CONNECT THE EQUIPMENT

The 407mm Equipment And Material Interfaces

Understand the role of each connection before building the equipment package.

  1. 01Compatible stored dry powder
  2. 02407mm inlet connection
  3. 03407mm mechanical screw conveying
  4. 04Receiving powder weighing system
Cement Silo series illustrationINTERFACE 01 / Cement Silo

Cement Silo / 407mm

The 300T and 500T associations point to larger storage duties.

Confirm For 407mm

Confirm the final outlet, isolation and connection arrangement.

Review Cement Silo
Stationary Concrete Batching Plant series illustrationINTERFACE 02 / Stationary Concrete Batching Plant

Stationary Concrete Batching Plant / 407mm

High-volume batching may justify this transfer class only after the actual recipe cycle is known.

Confirm For 407mm

Assess feed control and the receiving scale.

Review Stationary Concrete Batching Plant
Foundation Free Concrete Batching Plant series illustrationINTERFACE 03 / Foundation Free Concrete Batching Plant

Foundation Free Concrete Batching Plant / 407mm

A modular base requires its own screw support and alignment design.

Confirm For 407mm

Do not assume the largest diameter fits existing module clearances.

Review Foundation Free Concrete Batching Plant
Cement Feeder series illustrationINTERFACE 04 / Cement Feeder

Cement Feeder / 407mm

Bulk cement replenishment and discharge conveying need separate specifications.

Confirm For 407mm

Identify each endpoint and duty before ordering either component.

Review Cement Feeder

Options and alternative architectures are identified in each explanation. This is not a pre-approved matched package. Final connections, duty and supplied components require a model-specific technical review.

Review My Equipment Combination
407mm / COMPONENT EXPLANATION

Exploded Functional Overview

Separate the key systems to see what each contributes to the operation.

01Inlet flange02Screw & enclosure03Drive assembly04Discharge flange

407mm functional separation illustration. Blocks identify subsystem roles; they do not reproduce the machine geometry, assembly sequence or fastening details. Request the approved model drawing for engineering use.

Request The 407mm Assembly Drawing
407mm / PUBLISHED CONFIGURATION

Technical Data For 407mm

Parameter407mm
Inlet flange A (mm)470
Inlet flange B (mm)470
Inlet flange C (mm)530
Inlet H1, 0–20° (mm)750
Inlet H1, >20–40° (mm)900
Inlet H1, >40–50° (mm)1000
Outlet H2, 0–20° (mm)450
Outlet H2, >20–40° (mm)600
Outlet H2, >40–50° (mm)700
Reference capacity170t/h

Published EPDAS specifications are a reference for equipment selection. Final specifications and included equipment are confirmed in the quotation. Conveying capacity depends on material, inclination, length and feed conditions. Installation flange dimensions must be checked against the final drawing.

Original EPDAS Technical Reference ↗
A MODEL-SPECIFIC COMPARISON

Compare 407mm With Nearby Configurations

Selection reference407mm · This model323mm273mm
Reference capacity170t/h110t/h80t/h
Inlet flange A (mm)470300300
Inlet flange C (mm)530380380
Inlet H1, 0–20° (mm)750550500
Outlet H2, 0–20° (mm)450400350

Consider Φ407 for a large powder-handling system after confirming the complete transfer duty and installation drawing.

PREPARE THE 407mm PROPOSAL

Agree The Package And Site Interfaces

01

Reference capacity: 170t/h

Confirm core equipment, options, buyer-provided systems, transport modules, inspection documents and support responsibilities in the quotation.

Your Business Enquiry

* Required fields

EPDAS uses these details to respond to your equipment enquiry. For corrections or removal, contact info@epdas.com.

Discuss Your Project ↗