HBT40S-10-45
The smallest electric trailer concrete pump listed.
Explore HBT40S-10-45A trailer concrete pump receives concrete from a separate mixer, batching plant or truck mixer and transfers it through a pipeline. Compare electric HBT models with diesel DHBT models around output, pressure, power supply and delivery route.

It receives concrete from a mixer, plant or truck and pumps it to the pour. It does not produce the concrete itself.
Images show an equipment configuration. Specifications and included equipment depend on the selected model and quotation.
Building work, civil construction and placements requiring a planned concrete pipeline.
Required output, concrete mix, aggregate size, delivery height, horizontal distance and power supply.
Open a model to explore its specific strengths, published configuration and project fit.
The smallest electric trailer concrete pump listed.
Explore HBT40S-10-45A step up in electric delivery pressure.
Explore HBT50S-12-55Electric pumping in the 60 m³/h class.
Explore HBT60S-13-90The largest electric HBT output in this range.
Explore HBT80S-13-110Diesel pumping with a 118 kW engine.
Explore DHBT60-13-118Keep the output class. Increase the pressure reference.
Explore DHBT60-16-145More diesel delivery volume at 12.5 MPa.
Explore DHBT80-13-145The top diesel output-and-pressure combination listed.
Explore DHBT80-16-174Trailer pumping documented across a multi-area facility.
Explore DHBT40A separate configuration to discuss from the supplied range.
Explore DHBT60-12-82Scroll horizontally to compare all specifications.
| Parameter | HBT40S-10-45 | HBT50S-12-55 | HBT60S-13-90 | HBT80S-13-110 |
|---|---|---|---|---|
| Theoretical max. discharging volume (m³/h) | 40 | 50 | 60 | 80 |
| Theoretical max. delivery pressure (Mpa) | 10 | 12 | 12.5 | 12.5 |
| Delivery distance Vertical (m) | 120 | 150 | 180 | 180 |
| Delivery distance Horizontal (m) | 300 | 350 | 700 | 700 |
| Distribution valve type | S valve | S valve | S valve | S valve |
| Hopper capacity (L) | 600 | 600 | 600 | 600 |
| Feeding height (mm) | 1400 | 1400 | 1400 | 1400 |
| Inner dia. of delivery pipe (mm) | Φ125 | Φ125 | Φ125 | Φ125 |
| Main motor power (Kw) | 45 | 55 | 90 | 110 |
| Dimension (length ×width ×height) (mm) | 4970×1680×2580 | 5270×2000×1840 | 6170×1800×2100 | 6170×1930×2100 |
| Overall weight (Kg) | 3200 | 3500 | 5100 | 5200 |
Scroll horizontally to compare all specifications.
| Parameter | DHBT60-13-118 | DHBT60-16-145 | DHBT80-13-145 | DHBT80-16-174 |
|---|---|---|---|---|
| Max. Theoretic delivery volume (m³/h) | 60 | 60 | 80 | 80 |
| Max. Theoretic delivery pressure (Mpa) | 12.5 | 15.7 | 12.5 | 15.7 |
| Max. Theoretic delivery height (m) | 180 | 250 | 180 | 250 |
| Max. Theoretic delivery distance (m) | 700 | 1000 | 700 | 1000 |
| Type of distribution valve | S valve | S valve | S valve | S valve |
| Hopper capacity (L) | 600 | 600 | 600 | 600 |
| Inner diameter of delivery pipe (mm) | Φ125 | Φ125 | Φ125 | Ф125 |
| Diesel engine power (Kw) | 118 | 145 | 145 | 174 |
| Max. Oil pressure of main system (MPa) | 32 | 32 | 32 | 32 |
| Max. Oil pressure of mixing system (MPa) | 14 | 14 | 14 | 14 |
| Dimension (length ×width ×height) (mm) | 6600×1930×2190 | 6600×1930×2190 | 6600×1930×2190 | 6600×1930×2190 |
| Overall weight (Kg) | 5500 | 6000 | 6000 | 6500 |
Published EPDAS specifications are a reference for equipment selection. Final specifications and included equipment are confirmed in the quotation. Maximum output, pressure, vertical height and horizontal distance are separate reference limits. They are not simultaneous guaranteed operating points; concrete properties and pipe layout affect performance.
EPDAS product referenceNo. It needs an external concrete supply, such as a batching plant, separate mixer or truck mixer. Match the supply rate to the intended pumping operation.
Compare available site electricity, operating duty and movement between work areas. Confirm voltage and frequency for electric models and engine configuration for diesel models.
Match arrival and discharge of concrete with the intended pumping rate. Hopper supply interruptions affect delivery even when the pump has spare rated capacity.
A route combines elevation, pipe sections, bends and receiving conditions. Review the complete layout instead of adding maximum vertical and horizontal ratings.
Agree how the line will be cleaned, where residue will be managed and how communication will work between the pump and placing area.
Review mobile production where the work has no separate concrete source.
Explore Mobile Concrete Batching PlantConsider a separate placing boom where its supported working envelope fits the application.
Explore Spider BoomFunctional schematic for selection. It is not a dimensional drawing or a confirmation of items included in the quotation.
An external mixer, plant or concrete delivery vehicle.
The selected concrete transfer unit.
Pipe route, bends and receiving position matched to the duty.
| Configuration area | Reference scope | Options / confirmation |
|---|---|---|
| Core equipment | Trailer Concrete Pump and its published configuration. | Approve the exact model, component list and duty before order. |
| Supporting systems | Concrete source, delivery and placement interfaces. | Confirm what is supplied, optional or provided by the buyer. |
| Custom / private label | Custom configuration and branding discussions are supported. | Agree artwork, colours, markings, electrical requirements and documentation scope. |
Request dimensions, module weights, support layout, working clearances and utility connections for the selected configuration. Final transport and lifting plans follow the approved equipment scope.
Request Engineering DocumentsRequest available model-specific operation footage, factory inspection information and the proposed acceptance checklist. Agree the identification and records required for your procurement process.
Discuss Inspection RequirementsReview published model references before requesting the detailed technical pack.
Download CSV ↓