Electric trailer concrete pumps

HBT80S-13-110 Trailer Concrete Pump

HBT80S-13-110 raises theoretical delivery to 80 m³/h with a 110 kW main motor. Maximum listed concrete pressure remains 12.5 MPa.

EPDAS Trailer Concrete Pump series reference for HBT80S-13-110

Series rendering. Confirm HBT80S-13-110's appearance and included equipment in its proposal.

WHAT IS HBT80S-13-110?

Higher Electric Delivery Volume At The Same Pressure Class

A 110 kW motor accompanies the 80 m³/h theoretical output while listed maximum pressure stays at 12.5 MPa.

WHERE IT WORKS

Choose this configuration for comparison where concrete supply and electrical capacity can justify increased volume without a higher pressure reference.

01

HBT80S-13-110 Configuration

It offers more theoretical volume than HBT60S while sharing the same published pressure reference.

02

HBT80S-13-110 Selection Detail

The 5,200 kg machine weight and 1,930 mm width provide distinct transport-planning values.

HBT80S-13-110 / CONNECT THE EQUIPMENT

The HBT80S-13-110 Equipment And Material Interfaces

Understand the role of each connection before building the equipment package.

  1. 01External mixed-concrete source
  2. 02HBT80S-13-110 receiving hopper
  3. 03HBT80S-13-110 pumping and planned line
  4. 04Pour area or supported placing boom
Stationary Concrete Batching Plant series illustrationINTERFACE 01 / Stationary Concrete Batching Plant

Stationary Concrete Batching Plant / HBT80S-13-110

The higher output class depends on reliable upstream dispatch.

Confirm For HBT80S-13-110

Assess receiving trucks and peak concrete demand alongside the plant schedule.

Review Stationary Concrete Batching Plant
Mobile Concrete Batching Plant series illustrationINTERFACE 02 / Mobile Concrete Batching Plant

Mobile Concrete Batching Plant / HBT80S-13-110

Project-site production must deliver actual usable flow.

Confirm For HBT80S-13-110

Compare interruptions, discharge transfer and the published plant range with pump reception.

Review Mobile Concrete Batching Plant
Spider Boom series illustrationINTERFACE 03 / Spider Boom

Spider Boom / HBT80S-13-110

Added distribution requires a volume and pressure review together.

Confirm For HBT80S-13-110

Do not infer extra reach from the larger motor.

Review Spider Boom
Concrete Boom Pump series illustrationINTERFACE 04 / Concrete Boom Pump

Concrete Boom Pump / HBT80S-13-110

A boom pump offers another placing method for accessible pours.

Confirm For HBT80S-13-110

Compare the entire supply and setup chain with this electric pipeline option.

Review Concrete Boom Pump

Options and alternative architectures are identified in each explanation. This is not a pre-approved matched package. Final connections, duty and supplied components require a model-specific technical review.

Review My Equipment Combination
HBT80S-13-110 / COMPONENT EXPLANATION

Exploded Functional Overview

Separate the key systems to see what each contributes to the operation.

01Concrete receiving hopper02Distribution & cylinders03Power & hydraulic drive04Delivery pipe connection

HBT80S-13-110 functional separation illustration. Blocks identify subsystem roles; they do not reproduce the machine geometry, assembly sequence or fastening details. Request the approved model drawing for engineering use.

Request The HBT80S-13-110 Assembly Drawing
HBT80S-13-110 / PUBLISHED CONFIGURATION

Technical Data For HBT80S-13-110

ParameterHBT80S-13-110
Theoretical max. discharging volume (m³/h)80
Theoretical max. delivery pressure (Mpa)12.5
Delivery distance Vertical (m)180
Delivery distance Horizontal (m)700
Distribution valve typeS valve
Hopper capacity (L)600
Feeding height (mm)1400
Inner dia. of delivery pipe (mm)Φ125
Main motor power (Kw)110
Dimension (length ×width ×height) (mm)6170×1930×2100
Overall weight (Kg)5200

Published EPDAS specifications are a reference for equipment selection. Final specifications and included equipment are confirmed in the quotation. Maximum output, pressure, vertical height and horizontal distance are separate reference limits. They are not simultaneous guaranteed operating points; concrete properties and pipe layout affect performance.

Original EPDAS Technical Reference ↗
A MODEL-SPECIFIC COMPARISON

Compare HBT80S-13-110 With Nearby Configurations

Selection referenceHBT80S-13-110 · This modelHBT60S-13-90HBT50S-12-55
Theoretical max. discharging volume (m³/h)806050
Theoretical max. delivery pressure (Mpa)12.512.512
Main motor power (Kw)1109055
Dimension (length ×width ×height) (mm)6170×1930×21006170×1800×21005270×2000×1840
Overall weight (Kg)520051003500

Choose this pump for comparison when concrete supply can sustain the larger output class and the site has sufficient electrical capacity.

PREPARE THE HBT80S-13-110 PROPOSAL

Agree The Package And Site Interfaces

01

Theoretical max. delivery pressure (Mpa): 12.5

02

Hopper capacity (L): 600

03

Feeding height (mm): 1400

Confirm core equipment, options, buyer-provided systems, transport modules, inspection documents and support responsibilities in the quotation.

Your Business Enquiry

* Required fields

EPDAS uses these details to respond to your equipment enquiry. For corrections or removal, contact info@epdas.com.

Discuss Your Project ↗